MK3L Residual Current Circuit Breaker
Model Number:
Place of Origin:
Added:2019-12-31
Views:
Telephone:86-020-81368772
Next Previous

Details

ManHua



MK3L

Residual Current Circuit Breaker

Functions

? Switching and Isolation function

? Protection against the effects of sinusoidal alternating earth fault currents

? Protection against Indirect contacts and additional protection against dire

ct contacts.

? Protection against fire hazard caused by Insulation faults

? Used In residential bulkllng.non-residential building,energy sourcesjndustry

and Infrastructure.

Instruction of type code

imk^l iryii

I *— RdBdresHual aratCrTAJdO.aO.IOO^OO

,---------Rated current(A): 16,25.40.63

I - Residual tripp characteristic

-----------------------------typezAC>A,S Design number

-----------------------------Series code

Construction and Feature

? Elegant appearance; cover and handle In arc shape make comfortable

operation.

? Contact position Indicating window

? In case of overload to protected circuit, RCCB handle tripsand stays at

central position, whlchenables a quick solution to the faulty line. The handle

cannot stay In such position when operated manually.

. Pruvidss protection against earth fault/ leakags current and function of Isolation.

? High short-circuit current withstand capacity.

? Applicable to terminal and pln/fbrktype bus bar connection

? Equipped with finger protected connection terminals Fire resistance plastic

parts endures abnormal heating and strong Impact

? Automatically disconnect the circuit when earth fault/leakage current occurs

and exceeds the rated sensitivity.

. Independent power supply and line voltage, a nd free from external Interference,

voltage fluctuation.

Technical specifications

? Standard:IEC61008-1

? Approvals:CB,CE,VDE(applylng)

? Type (wave form of the earth leakage sensed): AC A

? Tripping tl me type:general use .selectivity of S

? Numberof poles:2P,4P

? Rated current ln(A):16.25,40,63

? Rated voltage Ue(DC):250/500V

? Rated insulation voltage(^C):500V

? Rated frequency(Hz):50/60

? Rated residual currents ^(^):10(29.^),30,100,300

ManHua

Outline and Installation

dimensions

MK3L

Residual Current Circuit Breaker

? Rated conditional short-circuit current:

lnc=Ui c=6000ASCPDfuse 100AGg

? Making and breaking capacity(lm):1.000

? Rated impulse withstand voltage(1.2/50)Uimp(kV);8

? Dielectric test voltage at lnd.freq.for 1 mln.(kV):2.5

? Electrical life:(0-C)10.000

? Mechanical Iife:(0-C)20r000

? Degree of protection:IP40(top).IP20(terminal).with connected conductors

? Mounting posltion:any

? Conductor cross-sections

? Terminal could use for busbar connection thickness (mm):Q.8?2,

wiring(mma):1-25

? Terminals

? Terminal lightening torque(N.m):2.5-4

? The relatatlve humidity Is 95% when ambient temperatureCC): 55

? Storage temperature(r): -40*+70

? Altitude Max.(meters):2000

Features

? Electromagnetic type .voltage independent.

? The handle being sealable or equipped with padlock bracket avoids dangerous

operation changes(ONZOFF)

? The handle provides a clear Indication of the contact position

? Adequate printing of all data on the front provides long-term identification

Types

Both RCCBs and RCBOs are further divided into types depending on the

operating function:

? Type AC(^]:For which tripping is ensured for residual

sinusoidal allernating current,whether suddenly

applied or slowly rising.

? Type :For which tripping is ensured for residual

sinusoidal alternating currents and residual pulsating

direct current$,whether suddenly applied or slowly rising.

? Type S :For selectivity.wlth time-relay.

Tripping sensitivity data

? RCD with a rated residual current of maximum 30mA are used for personnel,

material and fire protection,as well as for protection against direct contact.

? RCD with a rated residual current of maximum 300 mA are used as preventative

fire protection in case of insulation faults.

? RCD with a rated residual current of 100mA coordinated with the earth system

according to the formula I n 50/R.to provide protection against indirect contacts.

? RCD with a rated residual current of 10 mA a re primarily used In areas that

represent an increased risk for personnel